Which of those would you like?
Comprehensive Bystronic Laser Error Code List: Troubleshooting Guide
These often indicate an interruption or failure in the High Voltage (HV) power supply. Error 246 / 249 – Laser Head/Flashlamp: bystronic laser error code list
Selected error codes, causes, and fixes Note: Code labels can vary by Bystronic model and control generation (ByVision, ByControl). Treat the examples below as a template—check your machine manual for exact code text.
– Issues with the drive motors, encoders, or movement limitations of the X, Y, or Z-axis. Which of those would you like
Top off the chiller reservoir with distilled water and designated additives. 3. Motion Control and Drive System Faults Error Code Description Primary Cause Troubleshooting Action Axis X Lag Error (Following Error) Mechanical binding or faulty servo drive. Check X-axis linear guides for debris; verify lubrication. E0512 Axis Y Limit Switch Reached Over-travel due to software glitch or bad homing. Manually jog the axis off the switch; re-home the machine. E0555 Z-Axis Collision Detected Cutting head struck a tipped workpiece or slag.
Software conflicts, communication bus failures, or axis positioning errors. Treat the examples below as a template—check your
The chiller is powered on and showing normal operating temperatures.
A dirty or burned protective window reflecting laser light back into the head. Faulty scattered-light sensor.
Navigate to the Service page -> Automation -> Manual Control .